H1 CAL
jeffrey.kissel@LIGO.ORG - posted 08:01, Thursday 15 October 2015 - last comment - 13:26, Tuesday 20 October 2015(22546)
Beginning Measurement Suite and Flipping H1 ETMY Bias Sign
J. Kissel

We're taking the IFO out of observation intent and beginning measurement prep for flipping the H1 ETMY bias sign. Stay tuned for detail aLOGs.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:01, Thursday 15 October 2015 (22548)
J. Kissel

DARM OLTGF Is Complete. Results saved and committed to 
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Measurements/DARMOLGTFs/
2015-10-15_H1_DARM_OLGTF_7to1200Hz_BeforeBiasFlip_A_ETMYL3LOCKIN2_B_ETMYL3LOCKEXC_coh.txt
2015-10-15_H1_DARM_OLGTF_7to1200Hz_BeforeBiasFlip_A_ETMYL3LOCKIN2_B_ETMYL3LOCKEXC_tf.txt
2015-10-15_H1_DARM_OLGTF_7to1200Hz_BeforeBiasFlip_A_ETMYL3LOCKIN2_B_ETMYL3LOCKIN1_coh.txt
2015-10-15_H1_DARM_OLGTF_7to1200Hz_BeforeBiasFlip_A_ETMYL3LOCKIN2_B_ETMYL3LOCKIN1_tf.txt
2015-10-15_H1_DARM_OLGTF_7to1200Hz_BeforeBiasFlip.xml
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 09:15, Thursday 15 October 2015 (22549)
J. Kissel

PCAL to DARM Transfer Functions complete. We're going to quickly run an A2L measurement, then open the beam diverters. After which, we'll try to preserve the lock by transitioning over to ETMX for DARM control. However, this will require turning the ETMX HV ESD driver back ON, and we're on 50% confident that the IFO lock can survive that turn on transient. Wish us luck!

PCAL 2 DARM results have been committed to 
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Measurements/PCAL/
2015-10-15_PCALY2DARMTF_7to1200Hz_BeforeBiasFlip_A_PCALRX_B_DARMIN1_coh.txt
2015-10-15_PCALY2DARMTF_7to1200Hz_BeforeBiasFlip_A_PCALRX_B_DARMIN1_tf.txt
2015-10-15_PCALY2DARMTF_7to1200Hz_BeforeBiasFlip.xml
Images attached to this comment
darkhan.tuyenbayev@LIGO.ORG - 18:25, Thursday 15 October 2015 (22552)CAL

DARMOLGTF model vs. meas. comparison plots from measurements prior to ESD bias sign flip are attached to this report.

Parameter files for these measurements and updated comparison scripts are committed to calibration SVN (r1673):

/trunk/Runs/O1/H1/Scripts/DARMOLGTFs/CompareDARMOLGTFs_O1.m
/trunk/Runs/O1/H1/Scripts/DARMOLGTFs/H1DARMparams_1127083151_kappa_corr.m
/trunk/Runs/O1/H1/Scripts/DARMOLGTFs/H1DARMparams_1128956805.m
/trunk/Runs/O1/H1/Scripts/DARMOLGTFs/H1DARMparams_1128956805_kappa_corr.m

Plots and a .MAT file with the models are committed to calibration SVN (r1673):

/trunk/Runs/O1/H1/Results/DARMOLGTFs/2015-10-15_H1DARM_O1_cmp_bfSignFlip_*.pdf
/trunk/Runs/O1/H1/Results/DARMOLGTFs/2015-10-15_H1DARM_O1_cmp_bfSignFlip_DARMOLGTF.mat

In the kappa corrected parameter file for the measurements taken on Oct 15 we used average kappas over 1 hour calculated from SLM tool starting at GPS 112894560. The values are listed below:

κtst = 1.057984
κpu = 1.021401
κA = 1.038892
κC = 0.989844
fc = 335.073564 [Hz]

For kappas used in parameter files for Sep 10 and Sep 23 see LHO alog comment 22071.

Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 13:26, Tuesday 20 October 2015 (22688)
For the record, we changed the requested bias voltage from -9.5 [V_DAC] (negative) to +9.5 [V_DAC] (positive).