H1 had a lockloss at 4:10utc where there was no obvious culprit (nothing seismic, but I forgot to look at strip tools to see anything obvious).
Commissioning Mode for A2L: Once in Nominal Low Noise, ran the A2L script, but unfortunately it had errors, and left the SDF with diffs (after getting some consulting with Jenne able to Revert the SDF). So spent about another 22min running & troubleshooting A2L recovery. Will send Jenne errors in A2L script session.
Then went to Observation Mode at 5:10utc.
Operators: Do not run A2L script until Jenne troubleshoots script. (had "Permission denied" errors, so maybe there's an issue of running script logged in as ops?).
Will put this "pause" in running A2L in the new Ops Sticky Note page.
I was able to run the a2l script on my account. The script cleared all the SDF after it's done as Jenne advertised. All is well.
For lack of a better place to write this, I'm leaving it as a comment to this thread.
The problem was that the results directory wasn't write-able by the Ops accounts, although it was by personal accounts. I've chmod-ed the directory, so the A2L script should run no matter who you are signed in as.
Please continue running it (instructions) just before going to Observe, or when dropping out of Observe (i.e. for Maintenence).