Chris, Patrick I am going to turn the CW injections back on at H1. We are currently in single-IFO mode right now. And since this is the first time we are going to turn these back on, as a precaution I will ask Patrick (the operator on shift) to turn the intent mode off. The intent mode should only be off for a couple minutes at most. I will make an aLog entry when this work is done and the intent mode is back on. To do this we will: * Turn the intent mode off *Turn off the output of the continuous injection filterbankMore specifically turn off INJ_CW and INJ_HARDWARE. There is a startup transient in INJ_HARDWARE that we do not want to enter into the ESD * log into h1hwinj1/ on a work station browser * start psinject using the monit web interface * After a short time (a few seconds) turn on the output of the continuous injection filterbank so we don't inject the startup transient * Turn the intent mode back on