The LHO SEI team has known about a .6-ish hz peak on the HAM3 ISI for a long time (see my alog 15565, December of last year for the start, Hugh has a summary of LHO alogs in the SEI log for more). I was working with Ed on a DTT template for the operators when I noticed it was now gone. Very strange. Looking a little closer, it seems to have been decreasing over the last couple of days to a week, and disappeared completely this morning about 7-8:00 UTC. Attached spectra are from ~0:00 UTC (red) and ~16:00 UTC (blue, when I found it was missing). Looking at random times over the last week, it looks like it may have been trending down.
Could someone in Detchar look at this peaks longish term BLRMS, say over the last month, or even over the last year since we found it? Pretty much every sensor in that chamber saw this, but the GS-13s are the best witness.
I checked the coherence of H1:SUS-PR2_M1_ISIWIT_L_DQ with some PEM sensors for frequencies around 0.6 Hz.
Note - it reappeared for a few hours on Oct 13 - picture at https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=22775