Reports until 13:53, Monday 19 October 2015
H1 General
patrick.thomas@LIGO.ORG - posted 13:53, Monday 19 October 2015 - last comment - 14:10, Monday 19 October 2015(22645)
Back to nominal low noise
Adjusted ETMX in pitch and yaw to lock X arm on green
Adjusted PSL diffracted power from 5.8% to 8.5% by changing REFSIGNAL from -2.00 V to -1.98 V.
Ran a2l script.

Holding off on going to observing mode to allow Sheila and Evan to perform scattering measurements on ISTC6. (WP 5566)
Also tracking down SDF diff for H1:PSL-ISS_SECONDLOOP_SIGNAL. The setpoint has F10 ON and it is OFF.
Comments related to this report
kiwamu.izumi@LIGO.ORG - 14:10, Monday 19 October 2015 (22647)

Thank you, Jenne and Patrick for pointing it out.

Since the PID loop of the ISS is very slow (much slower than 1 Hz), I do not expect significant impact on the interferometer noise performance. Oops.

patrick.thomas@LIGO.ORG - 14:03, Monday 19 October 2015 (22646)
FM10 should be OFF.

Kiwamu had Ed accept the SDF difference when it was ON.

It is now OFF. Kiwamu has changed the SDF setpoint back to OFF.
patrick.thomas@LIGO.ORG - 14:08, Monday 19 October 2015 (22648)
20:54 UTC Betsy to LVEA to turn on CDS wifi for Evan and Sheila
20:55 UTC Kyle and Gerardo to mid Y for leak checking
21:11 UTC Betsy to LVEA to check on wifi/issue logging into computer
21:18 UTC Betsy back
21:29 UTC Evan and Sheila done
~21:52 UTC Kyle and Gerardo back
22:02 UTC Kyle and Gerardo heading back to mid Y