Laser Status:
SysStat is good
Front End power is 32.13W (should be around 30 W)
Frontend Watch is GREEN
HPO Watch is RED
PMC:
It has been locked 11.0 days, 20.0 hr 27.0 minutes (should be days/weeks)
Reflected power is 1.917Watts and PowerSum = 25.65Watts.
FSS:
It has been locked for 0.0 days 3.0 h and 30.0 min (should be days/weeks)
TPD[V] = 1.512V (min 0.9V)
ISS:
The diffracted power is around 9.125% (should be 5-9%)
Last saturation event was 0.0 days 3.0 hours and 30.0 minutes ago (should be days/weeks)
Things to note:
The usual LRA out of range andVB program online warngins are red on SYSSTAT.adl