kyle.ryan@LIGO.ORG - posted 17:12, Monday 19 October 2015 - last comment - 07:11, Tuesday 20 October 2015(22656)
Y-mid leak location progress
Kyle, Gerardo 

Today we applied Ultratape against the spool and both sides of the stiffener around the entire periphery, in effect, bagging the inaccessible space between the stiffener ring and the spool.  Next, we made a small incision and inserted a 1/4" poly tube to allow us to pump the inside of this "tape bag".  The overall seal wasn't very effective due to the lack of access in the area of interest - between the spool and the support gusset which is also the area of the leak - but we were able to achieve < 300 torr inside the tape bag.  As expected, the Y-mid pressure responded accordingly.  

So, at this point we have the leak location narrowed down to approx. 1" x 3" at the overlap of the spool seam weld and stiffener stitch weld (poor fabrication technique!)  We have some ideas of how to better access this area which we will need to do before applying epoxy or equivalent to seal the leak.  

Comments related to this report
john.worden@LIGO.ORG - 17:35, Monday 19 October 2015 (22657)

Photos of test setup.

Images attached to this comment
michael.zucker@LIGO.ORG - 20:10, Monday 19 October 2015 (22659)
Outstanding detective work! Well done guys. 

And thank heaven it weren't a gate valve...

PS I think we should at least consider running a fusion bead from the inside instead of goop. Section can be vented, right?
rainer.weiss@LIGO.ORG - 07:11, Tuesday 20 October 2015 (22664)
Very good that the leak was found. Suggest that the test for ferritic steel be applied
to the region around the leak. The test rig for ferritic steel is currently at LLO. 
It was last used by Tomeka Lewis and Harry Overmier.
Useful to know if we are in trouble all around or this location was an anomoly.