PMC trigger level changed

The trigger reference level for the pre-modecleaner was changed from 1.35 to 1.10.  This change was accepted in SDF.  The reason for the change is

that with the previous value, the sequencer for the pre-modecleaner thought it was locked when clearly it wasn't.  The lower value was more consistent

with observation.

Comments related to this report
peter.king@LIGO.ORG - 11:45, Tuesday 20 October 2015 (22677)PSL
Trigger reference value set back to 1.35 because the pre-modecleaner locked on a non-TEMO0 mode after it was changed to 1.10