peter.king@LIGO.ORG - posted 14:24, Tuesday 20 October 2015 (22693)
H1 PMC
After getting the PSL back, Keita mentioned to me that the alignment into the IMC was off and that he would like
me to bring the pre-modecleaner body temperature back to where it was before the power outage, namely 304.5 K
(as indicated on the MEDM pre-modecleaner screen).  It was sitting at 304 K when Keita ask me.  To do this I
disabled the temperature loop and increased the heater offset.  I had increased the heater offset as high as
0.96.  Then the temperature reached 304.5 K, I locked the pre-modecleaner, reduced the heater offset back to
its previous value of 0.72 and re-engaged the temperature loop.

On a different matter, it might be that the reference level at the ~middle left hand side of the MEDM screen
may need some adjustment/tweaking.  For a long time, this was set to 1.35 (on the slider).  However at times
the pre-modecleaner had difficulty locking and that was because the value between the two less than signs was
larger than the upper limit.  So the front end model thinks the pre-modecleaner is locked even though it's
obviously not.  Reducing the reference level down to 1.2 or 1.1 solves the locking problem, however Jason and
I were informed that the pre-modecleaner locked on a non-TEM00 mode when it was set to 1.10.