james.batch@LIGO.ORG - posted 10:05, Wednesday 21 October 2015 (22720)
Restarted EPICS ioc for 3IFO dewpoint sensors
The power outage of yesterday caused the EPICS IOC to not exit completely, so the instructions to restart the process did not work.  I logged in to the computer running the process and manually killed the dewpoint process.  At this point the instructions to restart (in the CDS wiki) worked.  Data is now being collected from the dewpoint sensors.