Displaying report 1-1 of 1.
Reports until 14:34, Thursday 22 October 2015
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 14:34, Thursday 22 October 2015 (22749)
Charge plots from data taken Tuesday

Betsy writing on Kissel's account, but on behalf of Kissel for the most part...

 

Attached are the long trend plots of the ETM charge data taken last Tuesday after the power outage.  Stuart has added a new plot ala Kissel's request which plots ESD actuation strength.  This new plot will be useful in comparison against calibration's estimate of the actuation stregth from calibration lines, aka the parameter "kappa_TST" (for example alog 21817).  The sign flip of the ETMY bias voltage for a couple weeks ago seems to have turned the effective charge voltage back towards zero as expected.

Images attached to this report
Displaying report 1-1 of 1.