The re-calibrated C01 hoft data generated by DCS is ready for use.
The re-calibrated C01 hoft data generated by DCS is ready for use. It is available via NDS2 and will be published into LDR soon.

The calibration factors were not applied when generating this version of hoft. The calibration group will comment separately on the uncertainties in the C01 calibration. (The calibration group is working on applying the calibration factors which will result in another version of hoft.)

1. The times the re-calibrated C01 hoft cover are:

H1: 1125969920 == Sep 11 2015 01:25:03 UTC to 1128398848 == Oct 09 2015
04:07:11 UTC

L1: 1126031360 == Sep 11 2015 18:29:03 UTC to 1128398848 == Oct 09 2015
04:07:11 UTC

as per these alogs,

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=22392
https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=21464

and as documented here:

https://wiki.ligo.org/Calibration/GDSCalibrationConfigurations
https://wiki.ligo.org/LSC/JRPComm/ObsRun1#Calibrated_Data_Generation_Plans_and_Status
https://dcc.ligo.org/LIGO-T1500502

2. Users should use C00 hoft and DQ flags before/after the above times.

This means the O1 analysis chunk including Oct 09 2015
04:07:11 UTC might need parts a and b, using C01 and C00 data respectively.

3. These C01 specific DQ flags exist:

H1:DCS-MISSING_H1_HOFT_C01:1

H1:DCS-SCIENCE_C01:1
H1:DCS-UP_C01:1
H1:DCS-CALIBRATED_C01:1
H1:DCS-ANALYSIS_READY_C01:1
H1:DCS-INVALID_CALIBRATED_DATA_TST_C01:1
H1:DCS-INVALID_CALIBRATED_DATA_THREE_C01:1
H1:DCS-CALIB_FILTER_NOT_OK_C01:1

L1:DCS-MISSING_L1_HOFT_C01:1

L1:DCS-SCIENCE_C01:1
L1:DCS-UP_C01:1
L1:DCS-CALIBRATED_C01:1
L1:DCS-ANALYSIS_READY_C01:1
L1:DCS-INVALID_CALIBRATED_DATA_TST_C01:1
L1:DCS-INVALID_CALIBRATED_DATA_THREE_C01:1
L1:DCS-CALIB_FILTER_NOT_OK_C01:1

Summaries of the % "live" time are here:

https://ldas-jobs.ligo.caltech.edu/~gmendell/DCS_SegGen_Runs/H1_C01/html_out/Segment_List.html

https://ldas-jobs.ligo.caltech.edu/~gmendell/DCS_SegGen_Runs/L1_C01/html_out/Segment_List.html

And due to non-zero dataValid flags, L1:DCS-ANALYSIS_READY_C01:1 will
not include these segments,

1127128496 1127128592 96
1127353008 1127353104 96
1127387760 1127387856 96
1127435760 1127435856 96
1127687856 1127687952 96
1128122032 1128122075 43
1128122086 1128122128 42
1128320816 1128320912 96
Total duration = 661 seconds.

but will gain these, due to gaps that have been filled in:

1126981012 1126981079 67
1126981095 1126981474 379
1126981888 1126983568 1680
1126989208 1126989232 24
Total duration = 2150 seconds.

We will not lose any H1:DMT-ANALYSIS_READY:1 time, but will gain these,
due to gaps that have been filled in:

1126627282 1126627298 16
1126645233 1126645244 11
1126988688 1126988732 44
1127059230 1127059246 16
1127480460 1127480471 11
1127563235 1127563246 11
Total duration = 109 seconds.

3. For analysis ini files,

i. The frame-types are H1_HOFT_C01 and L1_HOFT_C01

ii. The STRAIN channels are:

H1:DCS-CALIB_STRAIN_C01 16384
L1:DCS-CALIB_STRAIN_C01 16384

iii. State and DQ information is also in these channels:

H1:DCS-CALIB_STATE_VECTOR_C01 16
H1:ODC-MASTER_CHANNEL_OUT_DQ 16384

L1:DCS-CALIB_STATE_VECTOR_C01 16
L1:DCS-CALIB_STRAIN_C01 16384

The bits in the STATE VECTOR are documented here:

https://wiki.ligo.org/LSC/JRPComm/ObsRun1#Calibrated_Data_Generation_Plans_and_Status