Reports until 15:29, Friday 23 October 2015
H1 INJ (DetChar, INJ)
christopher.biwer@LIGO.ORG - posted 15:29, Friday 23 October 2015 - last comment - 14:15, Sunday 25 October 2015(22782)
stochastic injection test
Chris B, Joe B

After LLO had locked again, Joe and I took the opportunity to perform the coherent stochastic injection. CW injections were off at both sites. And the intent bit was off at both sites.

For the LLO couterpart aLog entry see: LLO aLog 21999.

Waveform:

The waveforms injected were: https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/stoch/Waveform/SBER8V3.txt

Injection:

At H1 Chris performed the injection with the command:
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 SBER8V3_H1.txt 1.0 1129673117 -d -d  > log_stoch.txt

I've attached the log.

As we were doing the injection we noticed a range drop of ~10%.

IMPORTANT ACTION ITEM:

The end of the stochastic waveform was not tapered. So when the injection ended it introduced a large transient into the ETMY. Robot voice was activated. This needs to be fixed. The beginning was properly tapered.
Non-image files attached to this report
Comments related to this report
peter.shawhan@LIGO.ORG - 14:15, Sunday 25 October 2015 (22817)INJ
It looks like no one set the CAL-INJ_TINJ_TYPE EPICS channel prior to running awgstream.  At LHO it happened to be equal to 2, so this stochastic injection was logged in H1 ODC bits and in the DQ segment database as a burst injection.  At LLO it happened to be equal to 0, so this stochastic injection did not flip any of the type-specific bits in L1:CAL-INJ_ODC, although it did still flip the TRANSIENT ODC bit.  So, this stochastic injection should be represented in the segment database with the ODC-INJECTION_TRANSIENT flag, but not with the ODC-INJECTION_STOCHASTIC flag.