The DMT Viewer sessions (for seismic trends) on NUC5 had been closing out the last few days. The NUC5 instructions say this is probably due to memory loss, so rebooted the computer by clicking the button on the nuc computer.
Unfortunately, I didn't obviously see the computer come up on the TVs. Luckily Jim was here and tinkered with the TVs and saw that the TV switched to a different input source. So, had to switch it to HDMI (also had to switch the upper TV, which required a ladder).
I couldn't log in to the computer, so I had to pull a keyboard and mouse from another computer & logged in. (after this I could share the screen remotely).
I opened up the seismic DMT sessions. I wasn't sure how to open the rf45 session (Cheryl posted the link to that file...but do I need to ssh into a different session to run this?).
Final note: I could not get the mouse onto the bottom TV screen.
After a few hours noticed odd display on the low frequency seismic changes. Then I looked at the date for this session and it was for some time in August! Not sure why this was the case. I just hit RUN. Closed the session out and hit RUN again, and this time it was live with today's date.
Now can see that over the last 12hrs the useism has been trending up noticealby.