It may have gotten lost in all of the alogs over the weekend, but I mentioned in a comment to an old alog (22789) that we had not been getting any real data for the ETMY spot positions.
Since LLO is still down, and I've been here all day trying to get the IFO locked, I rewarded myself with ~15 minutes of A2L investigation.
It turns out that we have had the input to the ETMY L2 DITHER filter bank off, so we weren't actually dithering ETMY. So, that explains why all of the data we have been getting looked so poor. Anyhow, I have turned those on and accepted them in SDF, so when the oscillators turn on with the a2l script, we should actually be sending some signal out.