Displaying report 1-1 of 1.
Reports until 14:05, Tuesday 27 October 2015
H1 ISC
sheila.dwyer@LIGO.ORG - posted 14:05, Tuesday 27 October 2015 (22889)
PRMI to DRMI transition

We implemented a version of the PRMI to DRMI transition that Stefan did by hand 20698 a few weeks ago (22472).  It has worked a few times and not worked a few times, operators are using this only when the DRMI alignment is bad to improve alignment in PRMI. Here are plots of two examples of a sucessfull and unsucesfull transition.  (failure at 20:37:19 UTC today, Oct 27,  sucess at 10/26 23:35:05 UTC )  

In the failure, the PRMI lock was lost when the SRM suspension started to realign SRM, before any feedback came on.  Jeff and I changed the ramp time for SRM in the guardian to 10 seconds (I think the default is 2 seconds).  We will see if this helps the PRMI lock to survive realigning the SRM.  

Also, in the sucessfull attempt the SRCL feedback came on at a time that AS90 was high, and POP90 was low.  It might be that triggering the SRCL output on one of these channels would be better than POP18.  

Images attached to this report