TITLE: Oct 28 OWL Shift 7:00-15:00UTC (00:00-08:00 PDT), all times posted in UTC
STATE Of H1: Observing
SUPPORT: N/A
LOCK DURATION: Entire shift
INCOMING OPERATOR: Nutsinee
END-OF-SHIFT SUMMARY:
IFO still locked at 78Mpc. Wind Calm. Sei and µSei remain the same. 2 more ETMY glitches. No further oscillations occurred. Curious that when LLO broke lock we also experienced a dip in BNS range.
SUS E_T_M_Y saturating (Oct 28 08:19:22 UTC)
SUS E_T_M_Y saturating (Oct 28 08:32:10 UTC)
SUS E_T_M_Y saturating (Oct 28 09:19:04 UTC)
SUS E_T_M_Y saturating (Oct 28 09:57:46 UTC)
SUS E_T_M_Y saturating (Oct 28 11:39:19 UTC)
SUS E_T_M_Y saturating (Oct 28 11:57:32 UTC)
MID-SHIFT SUMMARY:
ACTIVITY LOG:
07:34 Oscillations: duration ~ 5 minutes. May correlate with a high SNR LF glitch that I observed on DMT Omega.
07:48 MICH (live) on NUC4 FOMW seems to be “breathing” somewhere between 6Hz and 20Hz. Perhaps this is tied in with the previous log entry?
07:57 Oscillation: @08:04 IMC-F_OUTMON(tidal) grew to +/- 5 cts. ASC-DHARD_Y & P grew to +/- 2000cts. total duration is ~ 12minutes. Correlating(?) DMT Omega glitch shows up at approx the start time of the oscillation
10:00 Reset GraceDB External Notification script
13:25 DARM glitched between 60Hz and 300Hz