minor change in ISC_LOCK guardian: ISS 2nd loop notifications

Per JimW's request (alog 23032), I edited the ISC_LOCK guardian such that it throws notification messages when the ISS 2nd loop fails in the engagement. I have reloaded ISC_LOCK and checked the code into the SVN.

The notification messages will be displayed (1) if the IMC_LOCK guardian falls back to the LOCKED state (which is the programmed failure sequence) and/or (2) if the engagement process takes more than 4 minutes. The below are the new version of the ENGAGE_ISS_2ND_LOOP state. The red lines are the ones I newly added.

 

* * * * * * in ENGAGE_ISS_2ND_LOOP * * * * * *

    def main(self):
        nodes['IMC_LOCK'] = 'ISS_ON'
        self.wait_iss_minutes = 4.0 # in [min]
        self.timer['ISSwait'] = self.wait_iss_minutes*60 # in [sec]


    @get_watchdog_IMC_check_decorator(nodes)
    @nodes.checker()
    def run(self):
        # notify when the ISS fails. 2015-Nov-3, KI
        if nodes['IMC_LOCK'] == 'LOCKED' or nodes['IMC_LOCK'] == 'OPEN_ISS':
            notify('!! 2nd loop engagement failed !!')    
        # notify when the ISS is taking too many minutes. 2015-Nov-3, KI
        if self.timer['ISSwait']:
            notify('ISS spent more than %d minutes. Check ISS'%(self.wait_iss_minutes))

        # if IMC arrives at the requested state, move on.
        return nodes['IMC_LOCK'].arrived

Comments related to this report
kiwamu.izumi@LIGO.ORG - 18:40, Tuesday 03 November 2015 (23083)

Later today, we confirmed that the ISC_LOCK guardian behaved as intended -- it displayed the messages when the ISS failed in the engagement. Also there were a few minor typos which are now fixed. The guardian code is checked into the SVN.