Displaying report 1-1 of 1.
Reports until 16:35, Tuesday 03 November 2015
H1 AOS
jason.oberling@LIGO.ORG - posted 16:35, Tuesday 03 November 2015 (23078)
OpLev Output Configuration Switch Survey

During today's maintenance period I surveyed the switch configuration of the Output Configuration Switch (OCS) for each SUS oplev (WP #5588).  The OCS is the small board with 4 banks of 8 switches each that attaches to the front of each oplev whitening chassis; it allows us to control the amount of whitening gain and filtering we apply to the oplev QPD signal.  The results of this survey have been gathered and posted to the DCC here: T1500556.  This document needs to be updated anytime the switch configuration of these OCSs changes; if anyone makes any changes to an OCS please let me know, via email or alog (preferably both), what you did so I can keep us up to date with the current OCS configuration.

Displaying report 1-1 of 1.