Displaying report 1-1 of 1.
Reports until 20:28, Thursday 01 October 2015
H1 SUS
betsy.weaver@LIGO.ORG - posted 20:28, Thursday 01 October 2015 - last comment - 09:46, Thursday 05 November 2015(22174)
HXTX MEDM channel typo

Today, I discovered that on all of the HXTX Aux Ch screens (SUS_CUST_HXTX_MONITOR_OVERVIEW.adl) each of the M3 stage indicator lights are COPY/PASTEs of the M2 ones.  The channel values are all reading the appropriate channels, but the visual is incorrect for M3.  See attached.

Need to fix...

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 09:46, Thursday 05 November 2015 (23136)

Disregarding my "HXTX" references above which should read "HXTS", I've fixed the error in the screen and committed it to SVN.

Screen address:

/opt/rtcds/userapps/release/sus/common/medm/hxts/SUS_CUST_HXTS_MONITOR_OVERVIEW.adl

Displaying report 1-1 of 1.