TITLE: Nov 6 DAY Shift 16:00-00:00UTC (08:00-04:00 PDT), all times posted in UTC
STATE Of H1: Observing
SUPPORT: N/A
LOCK DURATION: ≈5 hrs
INCOMING OPERATOR: Nutsinee
END-OF-SHIFT SUMMARY: There was a mysterious lockloss ≈7 hrs ago and I had some trouble re-locking (see activity log). After that, smooth sailing. Handing off to Nutsinee.
ACTIVITY LOG:
17:02 Robert into LVEA to install shaker
16:57 LockLoss
17:30 went 20 minutes trying to get PRMI locked. Ditched and went to initial alignment
17:56 Chris called to tell me he was leaving in a few to go doen X-Arm to do beam tube work. Joe will accompany.
18:15 First attempt at relocking failed. Problems with Y-arm and diff vco. Re-visited Y arm alignment. H1:SUS-ETMY_M0_LOCK_Y_OUT16 took a rather long time to decide where it wanted to settle down.
19:00 OMC locked on wrong mode: After playing with OMC guardian and LOCK_00, then tripping the OMC watchdog and having to request align a few times, I got OMC back locked on the proper mode. 19:18 NOTE TO SELF: make sure that after manually locking OMC to advance the OMC Guardian node to “READY_FOR_HANDOFF” before manually pushing DC_READOUT. D’OH!
19:58 Re-locked at NLN
20:01 set intent bit to Undisturbed
00:00 Set intent bit to Commissioning for Robert to do some injections. This is being done in cooperation with Livingston.