Reports until 18:15, Friday 06 November 2015
H1 ISC
nutsinee.kijbunchoo@LIGO.ORG - posted 18:15, Friday 06 November 2015 (23168)
Experimental violin mode filter made for 1009.6234Hz

When both sites went out of Observing I was going to take the opportunity to do some violin mode damping. However, we were ready to go on Observing before I get to damp anything (I didn't even finish making the filter). The modified filter bank is ETMY L2 DAMP MODE4 FM7 and FM8 (BP and -60deg). This frequency however was already damped by MODE10 filter bank but hasn't been included in the violin mode table. I will edit the table accordingly.