Reports until 13:11, Monday 09 November 2015
H1 CDS
david.barker@LIGO.ORG - posted 13:11, Monday 09 November 2015 - last comment - 15:06, Monday 09 November 2015(23250)
New O1 detailed CDS overview MEDM screen

I have created a more detailed CDS overview screen customized for O1 operations. It shows the same data as the non-detailed screen and additionally:

SDF data (number of  differences and reference file name)

Test Points (number of testpoints opened on the model)

If the SDF diff number is not zero, a red circle is shown. If the numer of testpoints is not zero a blue circle is shown. Note: calibration models are permitted 2 TPs before the circle is shown.

Non-zero CRC accumulated numbers are highlighted with a blue rectangle. A button has been added which permits the operator to clear the accumulated CRC counters.

The screen has been attached to the SITEMAP under the "O-1" pull down.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 13:13, Monday 09 November 2015 (23251)

note that the "DAQ Clear Accumulated CRC" button communicates with the DAQ data concentrator. It would be preferable to only press this when H1 is not in observation mode. The same goes for the command button next to the EDCU red/green status (labled with a single exclamation point) which lists non-connected EPICS channels.

thomas.shaffer@LIGO.ORG - 15:06, Monday 09 November 2015 (23256)OpsInfo

Tagging OpsInfo