tinj switched to use PINJX excitation channel
We have been running tinj so that it injects transient hardware injections into CAL-INJ_TRANSIENT_EXC.

I updated tinj to use CAL-PINJX_TRANSIENT_EXC, this is the hardware injection excitation channel that uses PCAL.

The procedure was:
  (1) Edit tinj.m to use CAL-PINJX_TRANSIENT_EXC
  (2) Stop tinj using the monit web interface
  (3) Compile run_tinj using the command (note I did not source anything into my env): mcc -R -nojvm -R -nodisplay -R -singleCompThread -m run_tinj
  (4) Commit changes to SVN
  (5) Restart tinj using the monit web interface

I tailed tinj.log and it was updating as expected. And checked that the run_tinj process was running with both monit and top.
Comments related to this report
christopher.biwer@LIGO.ORG - 16:50, Tuesday 10 November 2015 (23292)DetChar, INJ
tinj was updated at LLO as well. See: aLog entry