Displaying report 1-1 of 1.
Reports until 23:52, Thursday 12 November 2015
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 23:52, Thursday 12 November 2015 (23364)
Added BP filters to the violin RMS monitor

I added BP filters to:

H1:SUS-ITMX_L2_DAMP_MODE6_BL

H1:SUS-ITMX_L2_DAMP_MODE7_BL

H1:SUS-ITMX_L2_DAMP_MODE8_BL

H1:SUS-ITMX_L2_DAMP_MODE9_BL

H1:SUS-ITMY_L2_DAMP_MODE6_BL

H1:SUS-ITMY_L2_DAMP_MODE7_BL

H1:SUS-ITMY_L2_DAMP_MODE8_BL

H1:SUS-ITMY_L2_DAMP_MODE9_BL

H1:SUS-ETMY_L2_DAMP_MODE5_BL (broad BP)

The filters have been switched on and will be used in monitoring the violin mode second harmonics. I accepted all the changes in OAF SDF.

The space in ETMX violin RMS monitor has run out. If some of the filters are yours and you aren't currently using it please let me know if you could spare one so I can at least make a broad band filter for the ETMX second harmonics.

Displaying report 1-1 of 1.