ITM violin mode damping temporarily turned off

I have turned off the violin mode damping filters for IX and IY by zeroing their gains. Patrick accepted these into SDF so that we can go to observing.

This is meant to be temporary, i.e., for this one lock only.

The next time the interferometer comes into lock, the Guardian will turn on the normal violin mode damping settings. These settings will appear as SDF diffs (two on IX, and six on IY). These should be accepted into SDF.

 

We do not expect these modes to ring up during the course of the lock. However, if the mode height on the control room DARM spectrum around 500 Hz rises above 10−16 m/rtHz, the damping should be turned back on:

  1. Make sure the ramp times for the damping filter modules are at least a few seconds (currently they seem to be set to 10 s).
  2. The filters should already be configured to provide the right damping phase, so changing the filters should not be necessary.
  3. Start typing in gain settings. Refer to the values listed below. If the violin mode amplitude is much much higher than usual (e.g., it's off the scale on the control room DARM spectrum), it is wise to start with a small gain (e.g, gain of ±1) in order to make sure the suspension drive does not saturate. Then you can increase the gain in several steps, until the nominal setting is achieved.

A screenshot of the nominal IY damping settings is attached (I didn't take one for IX).

ITMX:

ITMY

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 11:14, Wednesday 04 November 2015 (23102)

Thanks to Jeff, Patrick, and Jim for babysitting this.

The second lock (after the earthquake) lasted about 10 hours. Strangely, the ITM first harmonics (which range from 500 to 505 Hz) do not all seem to ring down.

Non-image files attached to this comment
borja.sorazu@LIGO.ORG - 19:29, Wednesday 11 November 2015 (23332)

An analysis of this data to measure Q of the fundamental modes for ITMX and ITMY violin modes is reported in 23331. The few modes that show an actual ringdown have a Q of about 0.3e9.

borja.sorazu@LIGO.ORG - 20:33, Friday 13 November 2015 (23384)

An analysis of this data to measure Q of the 2nd harmonics for ITMX and ITMY violin modes is reported in 23383.