Title: Ops Owl Summary, 08:00-16:00UTC (00:00-08::00PT)
State of H1: trying to relock
Incoming Operator: JimW
Shift Summary: winds and useism kept the IFO down
Details:
- when I arrived the ETMX ISI was oscillating and that took until about 14:00UTC to "fix" though I don't' know what I did that had a good effect
--- I took the ISI to OFFLINE, then back to FULLY ISOLATED and engaging stage2 thew it into oscillations
--- I had to manually engaged stage2, and was confused by the ISI position not matching the setpoints, and will ask Jim, who's coming in at 8AM
--- I restored all guardian control and sent the ISI back to FULLY ISOLATED, and it went and is currently ok.
Current State:
- average winds at EY and EX and the Corner Station are now above 27mph according to LHO anemometers
- useism is slightly lower in the last 2 hours, end stations around 0.5 and Corner Station around 0.9
- IFO is struggling to get to CHECK IR