Displaying report 1-1 of 1.
Reports until 22:12, Monday 16 November 2015
H1 DetChar
jordan.palamos@LIGO.ORG - posted 22:12, Monday 16 November 2015 - last comment - 22:39, Monday 16 November 2015(23448)
Possible RF45 glitches again

Starting at approx 5:30 UTC we are seeing an (small) increase in glitches on the control room glitchgram FOM (Figure 1). We think this is a symptom of the RF45 related issues again as we noticed a jump in the RF45 coherence FOM during one of these glitches.Right now, it seems much less damaging then the last episode.

See spectrograms (specifically feature at ~350 seconds in):

Strain: https://ldvw.ligo.caltech.edu/ldvw/view?act=getImg&imgId=108900

RF45: https://ldvw.ligo.caltech.edu/ldvw/view?act=getImg&imgId=108901

This time, the trend of LSC-MOD_RF45_AM_CTRL_OUT_DQ shows nothing strange (Figure 2).

Images attached to this report
Comments related to this report
jordan.palamos@LIGO.ORG - 22:39, Monday 16 November 2015 (23449)

The only reason I said the increase in glitches was 'small' is because I was comparing it to this.

It seemed to go away for ~40 mins but now it has returned again at ~6:32 UTC, looking pretty bad. I think Ed is going to try something.

Displaying report 1-1 of 1.