H1 out of Observing mode- RF45AM making the rounds again

Excerpt from my activity log;

06:32 45RFAM glitching for 5 minutes straight.

06:38 With Livingston down I came out of Observing to try and reduce the RF Set on the EOM to try and settle the glitching down.

06:44 Glitches still seem to be present only not as prominent to us. ASAIR_B_RF90 is becoming unstable looking. No saturations being reported.

06:55 Concerned about saving the lock, I called Jenne. There doesn’t seem to be any action to take regarding this issue other than to aLog it. While we’re talking RF45 is settling down. I’ll wait until our range is back to where it was previously before setting the intent bit back to observing.