Reports until 01:39, Tuesday 17 November 2015
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 01:39, Tuesday 17 November 2015 - last comment - 06:15, Tuesday 17 November 2015(23456)
Couldn't lock ALS. Doing an initial alignment.

Unable to maximize the ALS transmitted power just by touching ETMs and TMS alone. ITMs didn't move much compared to where it was after the lockloss. COMM beatnote is low (3ish) and touching PR3 didn't improve it.

Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 01:40, Tuesday 17 November 2015 (23457)

Another 5.4M earthquake from Greece coming through...... Pause the initial alignment.

nutsinee.kijbunchoo@LIGO.ORG - 01:49, Tuesday 17 November 2015 (23458)

We also just had a wind gust at ~50 mph. EQ band seismic is on the rise. Relocking is going to be a while......

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 03:02, Tuesday 17 November 2015 (23459)

First try relocking. Lockloss at REDUCE_CARM_OFFSET (11:02:17 UTC). Wind speed ~30 mph.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 03:11, Tuesday 17 November 2015 (23460)

Wind reaching 40 mph. Locking seems hopeless right now. Just lost lock again at CARM_ON_TR (11:08:2 UTC). Put ISC_LOCK to DOWN.

nutsinee.kijbunchoo@LIGO.ORG - 04:48, Tuesday 17 November 2015 (23461)

I noticed SRC_CAGE_SERVO user message tells me to "Align SR3 to offload M2 actuators". I'm not what action to take but I've attached the cage servo output below. I also noticed OMC shutter was opened while locking DRMI couple of times. Could that have intefered with DRMI locking? I don't remember the shutter being opened that early.

Tidal still high. Relocking still unsuccesful.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 05:50, Tuesday 17 November 2015 (23462)

Wind speed decreased to ~20mph. So I tried again. Lockloss while locking PRMI. Looks like ETMX ran away.

Images attached to this comment
nutsinee.kijbunchoo@LIGO.ORG - 05:59, Tuesday 17 November 2015 (23463)

Wind speed is back to ~30 mph.

nutsinee.kijbunchoo@LIGO.ORG - 06:15, Tuesday 17 November 2015 (23464)

The forecast lied to me saying the wind speed would decrease towards the morning. The wind has been 30-40 mph since 10 hours ago with no sign of decreasing. LLO has been down also because of wind. I'm calling it a night (or morning?).

Images attached to this comment