Displaying report 1-1 of 1.
Reports until 13:10, Tuesday 17 November 2015
H1 AOS (DetChar, INJ)
christopher.biwer@LIGO.ORG - posted 13:10, Tuesday 17 November 2015 (23475)
Update tinj to use CAL-PINJX for EPICs records
I've updated tinj.m to use CAL-PINJX_TINJ* instead of CAL-INJ_TINJ*. The new changes have been implemented at LHO.

The EPICs records changed are:
  * H1:CAL-PINJX_TINJ_STATE
  * H1:CAL-PINJX_TINJ_START
  * H1:CAL-PINJX_TINJ_ENDED
  * H1:CAL-PINJX_TINJ_TYPE
  * H1:CAL-PINJX_TINJ_ENABLE
  * H1:CAL-PINJX_TINJ_PAUSE
  * H1:CAL-PINJX_TINJ_OUTCOME

To do this:
  (1) Edited tinj.m to replace CAL-INJ_TINJ* with CAL-PINJX_TINJ*. The only exception was CAL-INJ_EXTTRIG_ALERT_TIME since ext_alert.py still uses this channel and has not been switched over yet.
  (2) At 20:57 UTC turned run_tinj off with the monit web interface.
  (3) Compile run_tinj using: mcc -R -nojvm -R -nodisplay -R -singleCompThread -m run_tinj
  (4) At 21:00 UTC turned run_tinj on with the monit web interface.
  (5) Commit changes.

I checked tinj.log and it was updating as expected.

We will need to coordinate the switch-over of CAL-INJ_EXTTRIG_ALERT_TIME to CAL-PINJX_EXTTRIG_ALERT_TIME. And update LLO to this version as well.