evan.hall@LIGO.ORG - posted 13:12, Thursday 19 November 2015 - last comment - 13:31, Thursday 19 November 2015(23567)
Simple mixer-based 45 MHz rfam monitor

Keita, Evan

We installed a mixer-based 45 MHz RFAM monitor using two spare 45 MHz spigots on the distribution amplifier on the ISC rack. This provides an unobtrusive way to look for 45 MHz amplitude glitches on the ISC rack (i.e., it does not require inserting anything into the main 45 MHz drive that goes to the EOM driver and the EOM). On the other hand, if the glitches are only on the main 45 MHz drive, this monitor will not tell us anything.

Set-up is as follows:

I have calibrated LSC-EXTRA_AI_1_OUT so that it is in volts. This channel is not dequeued, but if we have another hours-long episode of glitching we can watch the test points in real time.

Non-image files attached to this report
Comments related to this report
keith.thorne@LIGO.ORG - 13:31, Thursday 19 November 2015 (23570)CDS, DAQ
Took me a while to figure out that "not dequeued"  is really "not DQ-ed", which means that the channel is not in the permanent DAQ channel list (where it has the prefix _DQ).