Displaying report 1-1 of 1.
Reports until 16:59, Monday 05 March 2012
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 16:59, Monday 05 March 2012 (2358)
Fibers failure investigation

Here are some Dataviewer snapshoots of the event. Huge excitations start at 11:50am on March 1, 2012. (19:50 UTC)

Failure_3.png presents the coil drivers readbacks. Signals start going out of the coil drivers at 11:50am for no obvious reasons.

Models.png shows the last filter banks before the DAQ. The output channels are (:ISI-ST_MASTER_) and the 2 master switches are :ISI-ST_MASTER_SWITCHMON. All these signals were null at 19:50 UTC. This is not the case for the DAC channels (<IFO>-FEC_<DCU_ID>_DAC_OUTPUT_0_).

Failure_6.png shows the output channels of the ISI model and the DAC channels.

It seems that there are discrepancies between the ISI signals and the DAC signals.  

Images attached to this report
Displaying report 1-1 of 1.