The ISI blends are on Quite_90. The range is ~ 78 MPc. Relocking sequence: I had to move ETMX and ETMY in Pitch. I had to move TMSY in Pitch. I lost lock on SWITCH_TO_QPDS. I had to move ETMX in Pitch and Yaw. The ALS_DIFF node gave notifications on FIND_IR that 'X arm alignment is bad, not searching' and 'Y arm alignment is bad, not searching'. It eventually went to CHECK_IR without intervention. The ISC_LOCK node gave an 'IR not really found' notification on CHECK_IR. I adjusted H1:ALS-C_DIFF_PLL_CTRL_OFFSET to bring the IR in the Y arm to around 1. I lost lock on SWITCH_TO_QPDS. The ISC_LOCK node gave an 'IR not really found' notification on CHECK_IR. I adjusted H1:ALS-C_DIFF_PLL_CTRL_OFFSET to increase the IR in the Y arm but still got 'IR not really found' notifications. I decided to try to move to DRMI_LOCKED anyway. I lost lock on RF_DARM. I lost lock on FIND_IR. I started an initial alignment. The MC lost lock and relocked on LOCKING_XARM_IR. The X arm seemed to lock and then lose lock on IR. The MC lost lock and relocked. I set the X arm LSC gain to .15. The MC lost lock and relocked. I set the X arm LSC gain to .15 again. It did not seem to help. I set it back to .05. The X arm does not want to lock on IR. I put the ALS_XARM and ALS_YARM nodes to LOCKED_SLOW_W_ETM_WFS. I put the ALIGN_IFO node to SET_SUS_FOR_ALS. I increased H1:ALS-C_COMM_A_DEMOD_RFMON from around 4.1 to around 4.6 by moving PR3. I put the ALS_XARM and ALS_YARM nodes to UNLOCKED. I accidentally put the ALIGN_IFO node to INPUT_ALIGN_OFFLOADED. I quickly put it to INPUT_ALIGN. The X arm still does not want to lock on IR. I finally got the X arm to lock on IR by adjusting PR2 in Yaw from 4303.4 to 4302.4. I adjusted H1:ALS-C_DIFF_PLL_CTRL_OFFSET and H1:ALS-C_COMM_VCO_CONTROLS_SETFREQUENCY in CHECK_IR. It may have improved TRX. I stopped at ENGAGE_ASC_PART3 to wait for the ASC loops to converge. I reduced the ISS diffracted power. I engaged the ISS second loop by hand. I reached NOMINAL_LOW_NOISE.