Chris B., Keith R. Summary: Chris turned off the 3kHz PCALX line. Keith updated the CW injections to use PCALX and Chris tested it. Everything went well. Turned off the 2kHz line: The 3kHz PCALX line turned off at 18:37 UTC. I accepted the change for H1:CAL-PCALX_OSC_SUM_ON that changes the value from 1 to 0 on the SDF. Updated psinject config file: Keith R. updated psinject to inject into CAL-PINJX_CW_EXC. To do this Keith updated psinject_config.tcl and changed the line " set channel CAL-INJ_CW_EXC" to "set channel CAL-PINJX_CW_EXC". Chris did the following commands to update: cd /home/hinj/Details svn up psinject_config.tcl Tested CW injections on PCALX: CW injections were off at LHO already and the monit web interface has been disabled. See aLog 23666. So I turned off the CAL-PINJX_CW filterbank and did a test of psinject. To do the test I did: cd /home/hinj/Details/bin ./start_psinject ./check_psinject ./stop_psinject I checked that the CW injections were going to the correct channel. Everything looked fine. I then turned off psinject. I turned the CAL-PINJX_CW filterbank on.