Reports until 08:28, Thursday 26 November 2015
H1 CAL
patrick.thomas@LIGO.ORG - posted 08:28, Thursday 26 November 2015 - last comment - 08:58, Thursday 26 November 2015(23738)
Continuous wave injection is red on ops overview
From trending H1:FEC-117_GDS_MON_0 (the channel on the OPS overview) it looks like it changed around 21:35 UTC on Nov. 24. Is this because it was switched to PCAL X and the medm needs to be updated to use a different channel? alog 23701
Comments related to this report
david.barker@LIGO.ORG - 08:58, Thursday 26 November 2015 (23743)OpsInfo

good catch Patrick, yep it needs to be changed from CALCS to CALEX.