Observing
Kiwamu, Patrick

Switching the ISI blends to 45 mHz made all the difference. Accepted the SDF differences for the blends. (See attached screenshots). No problems as soon as we did that.

There is a yellow box with 'TPD' written in it flashing in the PSL area of the Ops overview. Kiwamu looked at the medm code and it appears when H1:PSL-FSS_TPD_DC_OUTPUT < 0.9. It is currently around 0.86.

There is still a testpoint open on H1LSC.
Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 22:02, Sunday 29 November 2015 (23815)

Good job, you guys!!  (And looks like you might have been up to 85Mpc for the first few hours?!  Wow.)