Reports until 02:21, Thursday 03 December 2015
LHO General (Lockloss)
thomas.shaffer@LIGO.ORG - posted 02:21, Thursday 03 December 2015 - last comment - 02:40, Thursday 03 December 2015(23925)
Lockloss 10:17 UTC

Not sure of the cause yet. Control signal Striptools didn't show any signs of struggle. Seismic looks calm, no wind.

Comments related to this report
thomas.shaffer@LIGO.ORG - 02:40, Thursday 03 December 2015 (23926)

HEPI tidal seems to have been good (1st attachment).

Lockloss tool is failing due to "IOError: [Error 28] No space left on device"

 

Looks like I am going to have to do an initial alignment, pretty much everything seems very misaligned...odd.

Images attached to this comment