evan.goetz@LIGO.ORG - posted 16:31, Thursday 03 December 2015 - last comment - 21:18, Thursday 03 December 2015(23939)
Elevated H1 glitch rate and elevated microseism

Currently ~6m wave activity off the Pacific Northwest coast causing elevated microseism. Omicron glitch rate correspondingly rises, especially in the low frequency region. I attach an image showing microseism trend and Omicron glitchgram. Can we get clues to upconversion mechanisms from IFO data during this time?

Images attached to this report
Comments related to this report
evan.goetz@LIGO.ORG - 18:12, Thursday 03 December 2015 (23940)

Evan G., Patrick T.

ISI Blend state is the same over this time period, nominal 45 mHz configuration (see attached). There was a brief time in the unlocked state where ETMX Y degree of freedom was switched but then switched back before relocking.

Wind is sub-10 mph.

Images attached to this comment
joshua.smith@LIGO.ORG - 21:18, Thursday 03 December 2015 (23944)DetChar, SUS
The summary pages show several optics, notably SRM and PRM, moving enough during this period to drive scattering fringes in the detection band. That's a likely cause for the low frequency glitches. Needs to be followed up to check the fringe prediction vs data for for some short specific times. https://ldas-jobs.ligo-wa.caltech.edu/~detchar/summary/day/20151203/detchar/scattering/