1. The re-calibrated C01 hoft data generated by DCS is ready for use up to 1129508864 == Oct 22 2015 00:27:27 UTC. It is available at CIT and via NDS2, and is being transferred via LDR to the other clusters. The times the re-calibrated C01 hoft now cover are: H1: 1125969920 == Sep 11 2015 01:25:03 UTC to 1129508864 == Oct 22 2015 00:27:27 UTC L1: 1126031360 == Sep 11 2015 18:29:03 UTC to 1128398848 == 1129508864 == Oct 22 2015 00:27:27 UTC This information has been updated here: https://wiki.ligo.org/Calibration/GDSCalibrationConfigurations https://wiki.ligo.org/LSC/JRPComm/ObsRun1#Calibrated_Data_Generation_Plans_and_Status https://dcc.ligo.org/LIGO-T1500502 (Note that jobs are running to generate C01 hoft up to Dec 03 2015 11:54:23 UTC, but this data will not be ready until after Dec 9.) 2. For analysis ini files: i. The frame-types are H1_HOFT_C01 and L1_HOFT_C01 ii. The STRAIN channels are: H1:DCS-CALIB_STRAIN_C01 16384 L1:DCS-CALIB_STRAIN_C01 16384 iii. State and DQ information is also in these channels: H1:DCS-CALIB_STATE_VECTOR_C01 16 H1:ODC-MASTER_CHANNEL_OUT_DQ 16384 L1:DCS-CALIB_STATE_VECTOR_C01 16 L1:DCS-CALIB_STRAIN_C01 16384 The bits in the STATE VECTOR are documented here: https://wiki.ligo.org/LSC/JRPComm/ObsRun1#Calibrated_Data_Generation_Plans_and_Status 3. For analysis segments and missing data segments use these C01 specific flags: H1:DCS-ANALYSIS_READY_C01:1 L1:DCS-ANALYSIS_READY_C01:1 H1:DCS-MISSING_H1_HOFT_C01:1 L1:DCS-MISSING_H1_HOFT_C01:1 Summaries of the C01 DQ segments are here: https://ldas-jobs.ligo.caltech.edu/~gmendell/DCS_SegGen_Runs/H1_C01_09to22Oct2015/html_out/Segment_List.html https://ldas-jobs.ligo.caltech.edu/~gmendell/DCS_SegGen_Runs/L1_C01_09to22Oct2015/html_out/Segment_List.html 4. Note that the same filter files are used for all C01 hoft generation: H1DCS_1128173232.npz L1DCS_1128173232.npz However, the C01 Analysis Ready time has been reduced from H1:DMT-ANALYSIS_READY:1 and L1:DMT-ANALYSIS_READY:1 by 3317 seconds and 9386 seconds respectively. This is because these options were used: --factors-averaging-time=128 and --filter-settle-time 148. (This allows study of the calibration factors stored in the C01 hoft frames, even though the calibration factors are not applied in C01.) 5. See these previous alogs: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=22779 https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=22000