H1 forensics - optical lever sum values for BS and ETMs and ITMs - glitching?

two plots attached: Dec. 1st and Dec. 5th - all while H1 is locked in Low Noise

Dec. 1st plot shows BS optical lever sum glitching by 200+ counts.

Dec. 5th plot of the same signals shows ETMY  optical lever sum glitching 50-70 counts, and ETMX optical lever sum gltiching 200+ counts, but BS sum is now quiet and +/-25 counts from the mean sum value.

Is this glitching, or an artifact of something else, and could this be effecting the IFO's locking?

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 20:24, Saturday 05 December 2015 (23978)

Red herring... Variation in signal is a small percentage of the sum.