Ops Eve Summary: 00:01-08:00UTC (16:00-23:59PT)
State of H1: down, ETMX ISI is oscillating
Help: Keita and Vern
Incoming Operator: JimW, who's looking into the ISI now
Shift Summary:
-
difficulties getting H1 to lock,
-
but after an initial alignment,
-
the DRMI did lock more than once,
-
but woulnd't hold,
-
the switch of ETMX ISI blend filters from (quiet90 to 45mHz),
-
threw the ISI into oscillation,
-
and while those oscillations have at times appeared to be dampled,
-
they came back and prevented locking,
-
so I switched ETMX blend filters to x dof = 45mHz, y dof = quite90,
-
after remembering that Jim had done this with some success in the past,
-
however this did not fix the oscillations either
Currently:
-
useism at CS is at 1um/s and increased throughout this shift, and appears to still be increasing
-
winds are below 5mph
As I was leaving I remembered an issue with ETMX guardian during my shift.
I ran INIT on the guardian for ETMX seismic, thinking it wouldn't do anything to the ISI, just refresh all the settings, so I would know that I was worknig with a good ISI guardian state.
What I got was guardian flashed, and then recovered, but in the process kicked up the ETMX oscillations.
I thought all INIT states were safe to run and not disturb hardware, but that's not how it turned out today.