Displaying report 1-1 of 1.
Reports until 10:43, Sunday 06 December 2015
H1 SEI
corey.gray@LIGO.ORG - posted 10:43, Sunday 06 December 2015 (23990)
Useism & Wind For O1 (looking at LVEA ITMy_Z for useism)

Attached are trends of useism & wind from August to present for E8/O1. 

MICROSEISM:  Clearly, useism has been growing with the season.  The worst storm was around 11/12 (but current one looks to be approaching that level, too).

WIND:  What made 11/12 storm worse was that it ALSO had winds over 40mph!  (For this current storm, winds have generally been under 10mph, BUT over the last few hours we had rain & now the winds are picking up to around 20mph (with an EX gust near 40mph). 

Will continue to monitor (the H1 range is running great at 78Mpc and no ETMy saturations thus far *knock on wood*).  And End Station ISIs look good with no ring-ups on the StripTool.

Non-image files attached to this report
Displaying report 1-1 of 1.