Reports until 10:53, Tuesday 08 December 2015
H1 TCS (DetChar, ISC, TCS)
jason.oberling@LIGO.ORG - posted 10:53, Tuesday 08 December 2015 - last comment - 11:54, Tuesday 08 December 2015(24046)
HWSx Polarizing Beam Splitter Install (WP 5627)

J. Oberling, N. Kijbunchoo, B. Weaver

This morning we installed the PBS in the HWSx path.  The 2 attched .png files show the desired before and after configuration of the HWSx beam path.  Unfortunately we did not have enough room to install the transmitted path as shown in the picture, so we moved HWSX_ALIGN_M1 and installed the lens and detector parallel to the reflected path (see before and after photos).  As it stands right now, HWSX_POSN_SENS2 is measuring the beam reflected from the PBS (s-pol (perpindicular)) and HWSX_POSN_SENS1 is measuring the beam transmitted by the PBS (p-pol (parallel)).  All optics are turned slightly to prevent back reflections from getting back into the IFO.  A short summary of our procedure:

Nutsinee noted the times we blocked each detector and will post that in a follow up comment to this alog.  This completes WP 5627.

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 11:54, Tuesday 08 December 2015 (24047)

Here's the time we blocked each detecter:

Detector1 blocked: 18:10:15 - 18:10:21 PST (GPS 1133633432 - 1133633438)

Detector2 blocked: 18:10:50 - 18:10:55 PST (GPS 1133633467 - 1133633472)

Images attached to this comment