Displaying report 1-1 of 1.
Reports until 22:45, Tuesday 08 December 2015
H1 SEI (ISC, Lockloss, OpsInfo, SEI, SUS)
cheryl.vorvick@LIGO.ORG - posted 22:45, Tuesday 08 December 2015 - last comment - 09:17, Wednesday 09 December 2015(24064)
ETMY ISI blend filters changed - big improvement in motion in Y and RX

Evan Hall suggested changing ETMY ISI blend filters after a couple lock losses between DRMI and ENGAGE_ASC.

The change from all Quiet_90s to Quiet_90 in X direction, and 45mHz in Y direction was easilly seen on ST1_ISO_RX and ST2_ISO_Y, and the ASC control signal in pitch being sent to the optic, ASC-ETMY_PIT_OUTPUT.

Plot attached shows those channels before and after the blend filter change, and ETMX ASC control signal, to compare.

Current blend filter config. medm is also attached.

Images attached to this report
Comments related to this report
richard.mittleman@LIGO.ORG - 07:48, Wednesday 09 December 2015 (24075)

Why are the y blends set different from the X blends?

evan.hall@LIGO.ORG - 09:17, Wednesday 09 December 2015 (24079)

Over the past month or so, having the 45 mHz blends on EX causes the ISI to ring up in full lock (for example: alog 23674 and comments).

Displaying report 1-1 of 1.