Evan Hall suggested changing ETMY ISI blend filters after a couple lock losses between DRMI and ENGAGE_ASC.
The change from all Quiet_90s to Quiet_90 in X direction, and 45mHz in Y direction was easilly seen on ST1_ISO_RX and ST2_ISO_Y, and the ASC control signal in pitch being sent to the optic, ASC-ETMY_PIT_OUTPUT.
Plot attached shows those channels before and after the blend filter change, and ETMX ASC control signal, to compare.
Current blend filter config. medm is also attached.
Why are the y blends set different from the X blends?
Over the past month or so, having the 45 mHz blends on EX causes the ISI to ring up in full lock (for example: alog 23674 and comments).