Reports until 18:45, Friday 11 December 2015
H1 ISC
jenne.driggers@LIGO.ORG - posted 18:45, Friday 11 December 2015 (24135)
New DRMI guardian state added - empty

As a potential solution to the BS oplev glitching problem that we were having earlier (before the oplev laser power was increased a bit), we had thought about creating a PRMI ASC state, much like the DRMI ASC state.  The idea was that we would try to engage ASC for MICH so that we could stop using the BS oplev for feedback. 

However, since the BS oplev seems to no longer be glitching, this is no longer a high priority.  So, the state still exists, but both the main and run parts have "if False" loops around all the code in them, so that this state is just a placeholder for now.  If we decide to go forward with ASC for PRMI, we've already got a healthy start on it.

The message is:  There is no practical change to the guardian code, although there is a new state if you open up the "all" screen on the ISC_DRMI guardian.