Reports until 12:04, Monday 14 December 2015
H1 SEI
patrick.thomas@LIGO.ORG - posted 12:04, Monday 14 December 2015 (24205)
end X ISI blends switched
Jim W., Evan H., Patrick T.

The end X ISI was ringing up. I took the IFO out of observing while Jim W. switched the blends. Both DOFs were on 45mHz and were switched to Quite_90. I accepted the SDF differences and returned the IFO to observing.

Screenshots of the accepted SDF differences and current blends are attached.

Out of observing from 19:34:07 to 19:54:02 UTC.
Images attached to this report