Reports until 14:25, Monday 14 December 2015
H1 SEI
hugh.radkins@LIGO.ORG - posted 14:25, Monday 14 December 2015 - last comment - 10:48, Tuesday 15 December 2015(24208)
Up dating ISI model

WP--5649, ECR E1500456, II 1167.  See aLog 23853 and SEI log 887 and 890.

In preparation for updating the ISI per above, I'm updating our local model and src areas:

hugh.radkins@opsws1:models 0$ svn st -u
?                    gnd_sts_library_NEW.mdl
        *    12022   isi2stagemaster.mdl
Status against revision:  12272
hugh.radkins@opsws1:models 0$ svn up isi2stagemaster.mdl
U    isi2stagemaster.mdl
Updated to revision 12272.
 

hugh.radkins@opsws1:src 0$ svn st -u
        *    11156   WD_SATCOUNT.c
?                    ISIWD_GPS_veryOLD.c
        *            BLENDMASTER_ST1.c
        *    10437   .
Status against revision:  12272
hugh.radkins@opsws1:src 0$ svn up
U    WD_SATCOUNT.c
A    BLENDMASTER_ST1.c
Updated to revision 12272.

hugh.radkins@opsws1:bscisi 0$ svn up
U    ISI_CUST_CHAMBER_ST1_BLEND_ALL.adl
Updated to revision 12272.
hugh.radkins@opsws1:bscisi 0$
 

I've successfully rebuilt all the ISI platforms.  Will wait until tomorrow for install & restart

Comments related to this report
hugh.radkins@LIGO.ORG - 10:48, Tuesday 15 December 2015 (24237)

FYI  The SATCOUNT.c update was a bug fix which applies to all ISI platforms.  This is why the HAMs were also rebuilt and restarted.  This fix will have the ISI saturations (seen n watchdog screen) clear immediately.  Added benefit for the BSC ISIs for not tripping those platforms from stale T240 saturations.  All good.