This is per the Ops Daily Check Sheet for a task to be done by a Monday Operator.
Laser Status:
SysStat is good
Front End power is 30.93W (should be around 30 W)
Frontend Watch is GREEN
HPO Watch is RED
PMC:
It has been locked 20.0 days, 13.0 hr 48.0 minutes (should be days/weeks)
Reflected power is 1.751Watts and PowerSum = 24.67Watts.
FSS:
It has been locked for 0.0 days 1.0 h and 21.0 min (should be days/weeks)
TPD[V] = 1.429V (min 0.9V)
ISS:
The diffracted power is around 8.255% (should be 5-9%)
Last saturation event was 0.0 days 1.0 hours and 21.0 minutes ago (should be days/weeks)